TruClimate 500
TruClimate 500 T5 20 to 80 Ton
Up To 22.4 EER
As Low As 0.536 kW/Ton

TruClimate 500
Water-Cooled Modular Reversible Scroll Chiller

Delivers simultaneous heated and chilled water throughout the building and is ideal for chiller banks.

removable 4-pipe header rack

Removable Header Rack Provide Flexible Applications

With our patented 6-pipe header rack design on the TruClimate 500, simultaneous heating and cooling set points are achievable from one chiller unit. Heat recovery provides use for energy that's typically wasted in other systems. The removable 4-pipe header rack design on the TruClimate 500 provides a wide variety of configurations to suit any building's needs.

6-pipe header rack design on the TruClimate 500

Premium Efficiency in a Convenient Cabinet

The TruClimate 500 Chiller product line utilizes premium efficiency scroll compressors housed in a compact cabinet for ease of installation. Optional permanent magnet DC inverter drive lead scroll compressor is available on the 30 and 50 ton module sizes to increase capacity turndown and efficiency.

Refrigerant, energy, and performance monitoring all through the HMI or through DDC protocols on touchscreen.

HydroLink2 Aurora Controls

The HydroLink2 Aurora controls platform provides numerous factory-installed options to provide better service, diagnostic, and monitoring ability. New features include refrigerant, energy, and performance monitoring all through the HMI or through DDC protocols.

Product Overview

Whether you're planning a new building or want to replace aging equipment, the TruClimate 500's modular cabinet design and patented 6-pipe removable header rack are a perfect fit. With industry-exclusive simultaneous heating and cooling capabilities, heat recovery, and industry-leading efficiencies, it becomes clear that our TruClimate 500 is Redefining Flexibility for the commercial and industrial markets.

Pump module connected to three TruClimate 500 linked via Hydrolink Supervisory Control

Remote HydroLink2 Supervisory Control

Multiple units can be staged together using the supervisory control for automatic and optimal staging of all units in a system. The supervisory controller can also accommodate additional controls including flow meters, pump controls, power analyzers, and additional sensors.

Multiple Remote HydroLink2 units in front of 6-pipe header rack

Modular Design

The modular design of the TruClimate 500 allows the units to be installed on an as-needed basis, and the detachable pipe rack allows for service on each module without compromising the rest of the system.

Oversized true brazed plate heat exchangers

Quality Components for Efficient Operation

Oversized true brazed plate heat exchangers offer high efficiency with industry-low waterside pressure drop as well as better part load efficiencies compared to two single circuit evaporators.

TruClimate 500 Chiller series heavy gauge galvanized, and powder coated steel enclosure features quick-turn latched access panels

Ease of Service

The TruClimate 500 Chiller series heavy gauge galvanized, and powder coated steel enclosure features quick-turn latched access panels that can easily be removed for ease of service. With the added benefit of quick-connect wiring harnesses, the entire control box can be removed in the field for increased service access.

Other Key Features

Factory-Installed Options

Factory mounted integrated four or six-pipe header rack constructed of 6" or 8" header pipe with grooved steel connections. Factory mounted, internally wired non-fused disconnect is also available.

Isolation and Bypass Valves

Factory mounted and wired isolation valves modulate water flow through each of the chiller modules in order to minimizing pumping power requirements through the chiller plant. Optional head pressure control of the water isolation valves extends the operating map of the chillers. Optional factory assembled bypass piping and valves allow water to flow through a single chiller module to prevent dead heading water from the circulating pump.

Circuit Breakers

Circuit breakers provide circuit protection and minimal downtime during maintenance.

Model
Nomenclature
Type
Unit Capacity
Efficiency
Compressor Type
Refrigerant
Cabinet Configuration
Discharge Configuration
Return Air Configuration
Hot Water Generation Choices
Soft Start Choices
Refrigerant Choices
Blower Motor Choices
Water Coil Choices
Water Control Choices
Control Choices
Electrical Choices
Cabinet Choices
Filter Choices
Air Coil Choices
Drain Pan Choices
Voltages
Model

TruClimate 500

Nomenclature

T5

Type

Water-to-Water

Unit Capacity

Number of sizes available: 7

20, 30, 40, 50, 60, 70, 80
265, 390, 510, 620, 805, 892, 990
Efficiency
5.9 to 16.8 EER



20.5 to 22.4 EER
0.536 to 0.584 kW/Ton

Compressor Type

Dual Scroll

Available Lead Variable Speed Scroll Compressor on 30 and 50 ton models

Refrigerant

R-454B

Cabinet Configuration

Modular Enclosure

Discharge Configuration

Not applicable

Return Air Configuration

Not applicable

Hot Water Generation

None

Soft Start Choices

Not applicable

Refrigeration Choices

EEV

Blower Motor Choices

Not applicable

Water Coil Choices

Brazed-Plate

Water Control Choices

Standard

Optional isolation valves

4-Pipe Standard or Dedicated Reversing

6-Pipe Standard or Reversing

Provisions for 4/6 Pipe

2.5", 6" or 8" Options

Control Choices

HydroLink Aurora (Standalone, BACnet, or LonWorks)

Electrical Choices

Breaker

Thru-the-Door Disconnect

Cabinet Choices

Powder Coated

Filter Choices

Not applicable

Air Coil Choices

Not applicable

Drain Pan Choices

Not applicable

Voltages

208-230/60/3

460/60/3

575/60/3